AlanBarrDone
===Really finished=== * RxDelay based on sendid ** [[ChrisLester]] has done this *Cut-down version of ... - request to Dave * FittingService can hang ** Hopefully solved by locked file IO. * Understand the ...
1K - last updated 2005-01-28 15:49 UTC by
AlanBarrToDo
== Top Priorities == * Comparisons of data should be to reference set rather than to "ideal case" * Monitoring ... SynchTriggerNoise should be a threshold scan ** Hopefully ok * sort out noise numbers for short endcap ... Trigger Noise -- Alan Phillips doing this * Slopes in gain, offset, noise -- See SlopesOnBarrelThree ...
1K - last updated 2006-07-07 22:25 UTC by
AnybodyToDo
== DAQUSER's WISHLIST == This is a list of things which if ANYBODY (who has time) did, would be very ... the alternative?) * ROD Errors to MRS ** Hopefully now does something reasonable ** Alter the ...
4K - last updated 2008-08-20 14:19 UTC by
BOC
The BOC (or Back Of Crate) module is part of the SctHardware. It is the primary data and control interface ... for the transmitted control signals, and other operations supported by the [[BPM]] chip. *provision ...
1K - last updated 2005-08-10 11:19 UTC by
Barrel3Analysis
There are several people doing analysis of [[Barrel3]] on data taken during assembly, and during warm ... notes] * Bilge's [[OPEAnalysis]] and [[DoubleTriggerAnalysis]] * Abdel's ... agenda] * SlopesOnBarrelThree by AlanBarr * SynchTriggerNoiseAnalysis ...
1K - last updated 2005-05-04 12:17 UTC by
Barrel3Exceptions
==The definitive list of known exceptions== * lmt01 Z+6 20220330200024 ** No redundant TTC (from harness ... test) * lmt03 Z+6 20220330200319 ** Noise slope in last 4 chips * lmt05 all ** Harnesses not tested ... lmt11 Z-2 20220330200341 ** One warm NO has high OPE at >1fC, lower face * lmt11 Z+6 20220330200353 ... TTC (from harness test) ** One warm NO has high OPE at >1fC, chip S12 * lmt16 Z-6 20220330200295 ... 1.87µA@500V) ** One cold NO has high OPE at > 1fC, chip S11 * lmt24 Z+3 20220330200446 ...
6K - last updated 2006-03-28 08:38 UTC by
Barrel4ColdTest
<b>MoPS Exceptions</b> * LMT04 Z-2 VVCSEL 5.0V * LMT04 Z-3 VVCSEL 5.0V * LMT04 Z-4 VVCSEL ... LMT40 Z-6 SELECT = 1 (Reduces [slightly] noise slope on LMT 40 Z-5) <b>Dead Vcsels</b> * ... anomalies</b> * LMT12 Z+2 DTN noise slope in last chip * LMT17 Z-6 DTN feature due to low ... vague stripes * LMT25 Z-6 DTN structured noise slope in last 2 chips * LMT34 Z-3 DTN stripes * LMT35 ... ~ bin 126 * LMT40 Z-6 3PG/DTN/NO offset/noise slope in last 2 chips, not a property of the module as ...
1K - last updated 2005-09-12 10:13 UTC by
Barrel4Exceptions
LMT2 Z+4 Link 0 DEAD VCSEL 1/2 normal current (failure of ileda?) * was later replaced by modifed module ... by KEK LMT12 Z+2 20220170200748 slight offset slope towards E13. NO to 3E-4 LMT14 z-1 20220330200646 ... link0 has the worst OPE blip. For a few events, it has full occupancy on ... at bin 7 - Chip S12 does not produce trailer properly as END. LMT40 Z-5 offset slope S12-E13 *Not ...
1K - last updated 2009-08-11 12:58 UTC by
Barrel5Exceptions
Features on [[Barrel5]] ==Modules which were replaced== * LMT02 Z-4 20220380200044 has been replaced ... that needed to be masked off for error free operation== * LMT04 Z-6 US176 ** One channel needed ... * LMT47 z+6 UK195 channel 812 ==Modules to be operated with SELECT 1== * LMT36 Z+6 JP690 ** If operated ... several neighbouring modules exhibit severe slopes in their offset and noise occupancy results. SELECT=1 ...
2K - last updated 2006-03-31 15:42 UTC by
Barrel6Analysis
=== Log books === * Electronic [http://www-pnp.physics.ox.ac.uk/~daquser/cgi-bin/sctroddaqsummary.cgi ... * DoubleTriggerAnalysis, ChipCounterTest and [[OPEAnalysis]] have now been updated with new results ...
4K - last updated 2005-08-12 15:42 UTC by
Barrel6ColdTest
A summary of [[Barrel6]] features applicable during the cold test... == B6 Z- ALONE == *NOT TESTED: ** ... is at very low threshold, well below the normal operating point, and the module works correctly at ... CH31) ==Offline== *LMT18 Z+2 shows noise/offsetslope for last two chips. Try SELECT=1 for this module ...
1K - last updated 2005-10-04 15:21 UTC by
BarrelConfig
Part of [[OxfordSetup]] Here we describe the format of pre-defined files that are used in SCT DAQ. These ... tested. Only after they are confirmed to work properly, the upper modules are mounted. Each barrel ...
3K - last updated 2005-07-14 11:25 UTC by
BilgeToDo
== In Progress== ?? == DONE == Thesis Debugging ROS issues during physics running Get TDC/ADC setup to ... new one. wrote report on Barrel3Analysis wrote [[OPETool]] ie. OccupancyPerEvent Analyser Tool arrange ...
1K - last updated 2007-05-13 19:44 UTC by
BlankMergePage
(See also MergingPagesForOmniMigration) First * Freeze SctRodDaq_3_0_BRANCH ** Chris sent mail 5th November ... asking all developers to cease commitals till this part of the merge ... ** Chris sent mail 13th August asking all developers to cease commitals till this part of the merge ...
2K - last updated 2005-02-16 19:02 UTC by
BocSetupTests
These tests are designed to setup the registers of the back-of-crate card ([[BOC]]). *RxDelayTest *RxThresholdBasedOnConfigRegisterTest ... There seems to be a ProblemWithBocSetupTests (hopefully now fixed) that casted doubt on their reliability, ...
1K - last updated 2006-12-11 16:50 UTC by
BoostOptional
Describe the new page here. <pre> gdb $SCT_DAQ_ROOT/installed/i686-slc3-gcc323-dbg/bin/CalibrationController ... #15 0x008cda68 in operator>>= (info=@0x985eec8, Info=@0xb6f7ff0) ... SctCalibrationController::SequenceRequestWorker::operator() ( this=0x9879550) at /scratch/tdaq/tdaq-01-04-01/installed/include/omniORB4/templatedecls.h:418 ...
1K - last updated 2005-12-06 13:49 UTC by
BruceGallopTodo
Most of this moved to SctApiToDo, what remains needs sorting. See also https://savannah.cern.ch/bugs/?group=atlassctroddaq, ... === Use DSP to read and write say RX threshold (hopefully avoid tx coarse delay problems). PWP added, ... Implement the changes needed to support physics operation in API? –Bruce ** Getting there ** Also ...
3K - last updated 2007-04-17 16:05 UTC by
BuildingARelease
Here are some instructions on building a new release of SctRodDaq: Before a release is built, please ... it as necessary. # Ensure the release is properly tested first! # Ensure that all the correct ... not. # Type: "make >& make.out&" and hope that everything works # The source and binary releases ...
1K - last updated 2005-01-26 14:32 UTC by
BuildingSctRodDaq
We are currently using the tip of TDAQ14_BRANCH The setup script depends on the account you are using: ... cp `find /atlas/daq/ext/ -name openide-lookup.jar` /usera/sctrod/lester-SLC4/SctRodDaq/installed/share/lib ...
1K - last updated 2007-03-16 10:44 UTC by
CDItesting
On pcphsctr04.cern.ch: From SystemTests, run AnalysisTests/NOTests/VariableTriggersTest/ -> put things ... * User: conditions * Pass: conditions Open the folder structure. Information on [[ISattributes]] ...
1K - last updated 2005-11-09 17:05 UTC by
CORBA
[[CORBA]] = Common Object Request Broker Architecture The [[CORBA]] is an architecture for distributed ... many processes on many different machines can operate on the same data objects regardless of where ...
1K - last updated 2008-05-29 09:42 UTC by
ChipConfiguration
This is the ABCD config register, each number is a field in the register as below (number on the right ... 1 = enable edge detection mask: 0 = normal operation 1 = send mask register to pipeline accumulate: ... 0 = clock feedthrough (clk/2) 1 = normal operation (ignored if not master) See ModuleConfig ...
1K - last updated 2008-03-03 13:27 UTC by
CorbaExceptions
Most useful ones (including CORBA::TERMINATE) are defined in [http://www.hep.phy.cam.ac.uk/~atlasdaq/FilesForWikiDownload/CORBA_Exception.h ... have removed the work around. So this issue is (hopefully) closed. ...
1K - last updated 2005-01-26 14:22 UTC by
DaqMeetingJune2005
For agreed actions see [[DaqMeetingJune2005ActionList]] ===Many-module "test" system(s)=== *Short-term: ... ** cooling, power supplies ** host location, operational effort etc. ===DAQ priority list=== The ...
1K - last updated 2005-06-30 08:48 UTC by
DaqMeetingJune2005ActionList
==Available test systems== ====Short-term test systems==== * [[Barrel5]] - the afternoon and evening ... and modifyABCDVarROD (single module) ## proper testing requires fix of SynchTrigs '''(done)''' ...
1K - last updated 2005-09-14 20:11 UTC by
DoubleTriggerAnalysis
This page documents the preliminary analysis of DoubleTriggerNoise data from Barrel 3, 4 and 6 cold runs ... 4 has a small peak. chip E13 has known noise slope which goes away in Select=1. 20220170200017 LMT30 ... LMT18 z+2 : Looks like a noise slope on chip S13. But still there is some time structure, ... and bad OPEs. Maybe electrical pickup? Noise slope shows up ... of [[Barrel4Analysis]] * LMT12 Z+2 DTN noise slope in last chip * LMT17 Z-6 DTN feature due to low ...
1K - last updated 2007-04-12 20:41 UTC by
DspPrimitivesReview
Based on primParams.h Haven't looked at primParams_sct.h properly, maybe Alan would comment on the current ... 4 primitives. I've just started looking at it properly, it's needed for reconfiguring modules on the ...
1K - last updated 2006-01-31 11:20 UTC by
DspToDo
As of 26/7/2005: * Synch triggers with assembly - histogram output * OPE with assembly * lemo output ...
1K - last updated 2005-07-26 16:06 UTC by
EndcapC Combined run
== General == Please keep an eye on the module HVs, LVs and temperatures during the run. On SctGUI - ... * Eventually the TDAQ IGUI (main DAQ GUI) will open * Make sure the run type is 'Physics' - if not, ...
3K - last updated 2006-12-08 17:07 UTC by
ErrorEventDecoder
This page describes the output of the Error Event Decoder which has now been incorporated into the DSP ... installations at CERN you will be able to open the latest log file by: <pre> ~/scripts/vitail ... (to open in VI) ~/scripts/katetail (to open in Kate) </pre> ...
6K - last updated 2009-09-11 17:23 UTC by
ErrorMaskRegister
The errorMask is used to mask known problems in events, set for a fibre as a sum of the following: 0x1 ... Trailer For upto date information see the ROD operations manual. ...
1K - last updated 2009-09-11 13:45 UTC by
HangingCalibrationController
== Mail of Wed, 1 Mar 2006 18:52:00 == <pre> Some Good News ! With some helpful suggestions from ... turned out to have no effect on the hanging properties FOR THIS PARTICULAR TEST, however they will ... your IPC based objects in the heap using the new operator 2. Never call the delete operator for them ... your IPC based objects in the heap using the new operator 2. Never call the delete operator for them ... your IPC based objects in the heap using the new operator 2. Never call the delete operator for them ...
1K - last updated 2006-03-01 19:04 UTC by
HardwareProblems
You shouldnt need this if you follow instructions for SettingUpDaqHardware There are numerous things ... the RODs are there...) not being seated properly (check the TIM first) * A ROD doesn't appear ...
1K - last updated 2005-03-24 01:19 UTC by
Hardware reference
This page will hopefully expand to contain pointers to Hardware documents. ==ROD== The latest version ... of ROD Operations Manual can be found here: Main text: https://uimon.cern.ch/twiki/pub/Main/AtlasSiliconRodGroup/operationsManual_050606.pdf ... Appendix B: https://uimon.cern.ch/twiki/pub/Main/AtlasSiliconRodGroup/operationsManual_appB_250506.pdf ...
1K - last updated 2008-02-06 21:07 UTC by
HomePage
==Overview== This Wiki is for discussing the SctRodDaq software. Although I see no reason why this couldn't ... * Wiki:WikiCase ==SctRodDaq software== Hopefully these pages will develop into useful resources ... are more generally available. The SoftwareDevelopers are the ones to blame for this! For agendas and ...
1K - last updated 2004-01-09 13:20 UTC by
HowToRunASystemTest
To run the system tests from a release file: # Set <code>SCTDAQ_ROD_CONFIGURATION_PATH</code> ... in the !TestConfig directory. # Run as above I hope this provides a useful-ish guide! ...
1K - last updated 2004-01-17 18:10 UTC by
ILU
[[ILU]] = Inter-Language Unification [[ILU]] is a distributed process system developed by Xerox. It pre-dates ...
1K - last updated 2004-06-29 11:40 UTC by
InterMap
AbbeNormal http://ourpla.net/cgi/pikie? AcadWiki http://xarch.tu-graz.ac.at/autocad/wiki/ Acronym http://www.acronymfinder.com/af-query.asp?String=exact&Acronym= ... http://www.emacswiki.org/cgi-bin/oddmuse/ OpenWiki http://openwiki.com/? PeriPeri http://www.srcf.ucam.org/~cjp39/Peri/ ...
1K - last updated 2003-11-21 14:30 UTC by
Jabber
Jabber is an open instant messaging system. * Users run client applications that connect to a server. ...
2K - last updated 2006-07-12 07:57 UTC by
JanuaryTestingWeek
==Aim== To find out any remaining problems with SctRodDaq which could compromise our ability to do stand-alone ... **PreTriggerNoiseTest <I>ok if proper NIM signal is sent</I> ***<I>could ... pmg agent wont start on pcphsctr03 *** Fixed by opening ports in firewall? (Ok now - AJB) === Other ... of full mode scans ** done AJB 30-1-2006 ** no OPE - since full mode scan ** occupancy seems higher ... boc (BG) * RxThr Lester improved (ok AJB) * OPE with full (PWP) * CC signal handling (CGL) * TDAQ ...
1K - last updated 2006-03-31 11:28 UTC by
L1IDSetup
All you ever need to know about L1IDs, but were afraid to ask: * ATLAS TDAQ counts the "first trigger" ... to know about BCIDs, but were afraid to ask: The operations manual has an EFB register called EFB_CMND_O, ...
1K - last updated 2006-03-10 10:21 UTC by
LinkMaskMonitoring
(1) Check out latest versions of SctRodDaq/CoolTools, and SctRodDaq/SctApi (2) Recompile (3) In the OKS ... /purple/pants which hopefully will become $SCT_DAQ_ROOT/SCT/COOL_Test/allRead ...
1K - last updated 2009-04-27 16:24 UTC by pcfk.hep.phy.cam.ac.uk
Meeting12October2005
===SCT DAQ Job List Following ID Week=== ====12th October 2005==== For SCT and Combined SCT/TRT running ... Implement the changes needed to support physics operation in [[API]] –[[Bruce]] ** Find out about ...
2K - last updated 2005-11-09 15:48 UTC by
Merge-C0-C3
(See also MergingPagesForOmniMigration) == Begin with merge of ONLINE21_BRANCH == First * Small team ... lead the merge with help from others. This will hopefully prevent too-many-cooks syndrome and allow ... it back to where it came from, and merged (hopefully) all changes from A1->C2 (the usual route) ... copy. || || No longer needs changes C0->C2, hopefully. || || ||sctConfIPC|| Alan & Chris|| done ...
1K - last updated 2004-11-06 17:35 UTC by
Merge-C4-C5
(See also MergingPagesForOmniMigration) First * Freeze SctRodDaq_3_0_BRANCH ** Chris sent mail 13th August ... asking all developers to cease commitals till this part of the merge ... ** Chris sent mail 13th August asking all developers to cease commitals till this part of the merge ...
3K - last updated 2004-11-06 19:26 UTC by
Merge-C6-C7
(See also MergingPagesForOmniMigration) First * Freeze SctRodDaq_3_0_BRANCH ** Chris sent mail 5th November ... asking all developers to cease commitals till this part of the merge ... * Freeze HEAD ** Chris sent mail asking all developers to cease commitals till this part of the merge ... for DcsData (version2) which is beyond the scope of this merge (was added to Release 3 8/11/04) ...
1K - last updated 2004-11-10 11:31 UTC by
Merge-C8-C9
(See also MergingPagesForOmniMigration) First * Freeze SctRodDaq_3_0_BRANCH ** Haz been frozen since ... ** Chris sent mail 13th August asking all developers to cease commitals till this part of the merge ...
7K - last updated 2005-11-02 10:37 UTC by
MergingPagesForOmniMigration
(See also OmniMigration) Summary Picture: http://www.hep.phy.cam.ac.uk/~atlasdaq/images/MergePic.multicrate.png ... == Described in [[Merge-C8-C9]] == Future ... hopefully there will be no more merges ... == Future ...
1K - last updated 2005-03-09 16:49 UTC by
MissingLinks
This page aims to give the definitive overview of known faults with the optolinks for all barrels. For ... test) * lmt24 Z+3 20220330200446 has noise slope with SELECT=0. Use SELECT=1. * lmt30 Z-5 20220170200009 ...
3K - last updated 2009-08-11 13:18 UTC by
ModuleDiagnostics
No response # Is the module power on? # Is Icc above 100mA? If not, no module is connected. # Is Idd ... returning 2 ** Diagnosis (alternative - Scope) tools->SctApiGui->RodDiagnostics->set ... but with "J" rather than "2" in the probe, or scope. ** Solution - adjust RxDelay and RxCurrent (perhaps ...
2K - last updated 2006-02-10 16:29 UTC by
OPE
[OPE]=OccupancyPerEvent i.e. number of hits per event per chip ...
1K - last updated 2004-07-22 17:49 UTC by
OPEAnalysis
Part of [[Barrel3Analysis]] OPEAnalysis analyses data from the [[OccupancyPerEvent]] Data using [[OPETool]]. ... at [http://www-pnp.physics.ox.ac.uk/~demirkoz/OpeData/ OPEData]. There are three plots for each module: ... longer to read it out. * Raw.2180.0.modulenumber_OPE_1.eps : contains histograms for each chip. The ... see [http://www-pnp.physics.ox.ac.uk/~demirkoz/OpeData/OpeExample.eps plot].) For the Binomial distribution, ... at [http://www-pnp.physics.ox.ac.uk/~demirkoz/OpeData/histbad.eps histbad.eps] or for a log plot, ...
2K - last updated 2005-08-11 12:20 UTC by
OPETool
OPETool is an analysis tool for OccupancyPerEvent or OPE data which is in Release4.0. OPETool takes in ... RawData and analyses the OPE data for each threshold bin separately. At each ... event is given by the Binomial distribution. The OPETool compares the observed variance of this distribution ... formula that relates mean to variance. The OPE "badness" parameter is defined as the ratio of ... The badness parameter is output to the OpeSummary and can be viewed in the online Gui. An ...
1K - last updated 2005-02-01 17:02 UTC by
ORB
[[ORB]] = Object Request Broker An [[ORB]] is a critical component of any [[CORBA]] implementation. Different ... may have different [[ORB]]s, but hopefully they all talk the same language to each other. ...
1K - last updated 2005-02-23 22:49 UTC by
OccupancyPerEvent
Helpful in trying to get a handle on common-mode noise pickup. The [[ROD]] [[DSP]]s can record the number ... a histogram. This is the occupancy per event [[OPE]] for that chip. A two-dimensional histogram consisting ... of [[OPE]] on the x-axis and scan point (threshold) value ... the total number of events. An example of an [[OPE]] histogram can be seen at http://www-pnp.physics.ox.ac.uk/~daquser/ExamplePlots/OPE_NO.eps ... data see DataDisplayerExamples Note that the [[OPE]] data was a new feature on <B>22nd July ...
1K - last updated 2005-05-26 16:58 UTC by
OnasicRecipes
[https://twiki.cern.ch/twiki/bin/view/Atlas/AtlasTDAQDataBaseONASIC Onasic documentation] == ! IMPORTANT ... available at run-time one has to setup properly the IS meta-information repository. This can ... </attr> <attr name="IGUIProperties" type="string" num="1"> "-Digui.panel=PmgGui.PmgISPanel" ... find the same situation ... although there are (hopefully unused) copies of Info Schema files under ...
7K - last updated 2008-08-05 14:02 UTC by pcatsct06.cern.ch
Overview
This Wiki is mostly out of date, see the SCT TWiki pages for more up to date info. Still most important ... etc. ==SctRodDaq software== The SoftwareDevelopers are the ones to blame for this! Please see the ...
1K - last updated 2009-01-14 14:12 UTC by
PointOneDcs
==Point 1 DCS== ==PVSS Systems== SCS Host System Number System Name KVM Channel Status PCATLSCTSCS 20 ... From any system on the pit network, you may open a remote desktop connection to any of the above ... normal user account "sctdcs", but if you wish to open a connection from the main CERN network you will ...
3K - last updated 2007-01-31 16:07 UTC by
Point 1 Setup
see also PointOneDcs == Introduction == All DAQ related servers, SBCs and ROSs are in USA15. We have ... * SCT GUI seems to start but doesn't open on the screen <pre> The gui has probably ... results in an exception, and the gui would still open, but under certain conditions the gui could hang. ... in the configuration. From the main DAQ GUI, open the panel entitled "Segment and Resource". Double ... then restart the DNS running on pcatlsctcr01. Hopefully DDC will now work for a little while, but ...
2K - last updated 2008-09-19 08:18 UTC by
PowerSupplySystemSetup
Part of OxfordSetup. * Start the PVSS II Version 3.0 Console ** Start/Programs/PVSS II 3.0/ PVSS II Console ... Press the little "wheel and bow tie" figure to open and run a panel ** Select the panel "SCT_Diagn_MoPS.pnl" ...
1K - last updated 2005-03-07 12:04 UTC by
ProblemsSeenInCurrentCode
6/10/2005 <pre> MDSP 1.20 Aug 11 2005 15:09:56 SDSP 1.20 Jul 26 2005 18:34:30 </pre> Testing ... is this an SctApi or a [[DSP]] problem? * [[OPE]] - not turned on with assembly ** I think this ... UseCCode. At one point I set this to use C for OPE as assembler OPE mucho plenty bomb worthy. PWP ... Good points: * Assembler histogramming without OPE looks very good and robust Not tested: * SynchTrigs ...
1K - last updated 2005-10-07 09:27 UTC by
ProblemsWithTextBuffers
List of problems with text buffers == Transfer buffer full == This occurs when the VME crate boots and ... now been shown to be a bottleneck for full-crate operation (seen when testing is cosmics run) -- this ...
1K - last updated 2006-06-30 08:44 UTC by
Releases
The current release of SctRodDaq is probably a version just off the top of the list below. *[[SctRodDaqRelease4.3]] ... expected to be useful to non-developers. *[[SctRodDaqRelease4.1]] -- (10th Feb 2005) ...
1K - last updated 2008-04-14 13:59 UTC by
RodTest
Used for debugging the [[ROD]] at a low level. Runs on the [[SBC]]. === Download === In the sctpixel ... The program interfaces many packages developed by the SCT-Pixel DAQ collaboration, notably VmeInterface, ...
1K - last updated 2003-12-01 17:56 UTC by
RxThresholdBasedOnConfigRegisterTest
==The method of this test is as follows:== * Configure modules to return the content of the ConfigurationRegister. ... only one link a lot == Updated the analysis to cope with situations like that shown in the following ...
1K - last updated 2006-07-05 15:35 UTC by
SctApiToDo
See SctApiTests for things that should be checked every time. Add Slave single write to RODDiagnostics. ... ones? == SR1 (ie 4 barrels) == Multi-crate operation: * Integration with ROD Crate DAQ ** This ...
4K - last updated 2007-04-17 16:33 UTC by
SctOnlineMonitoring
===Context=== The cosmics run with the barrel at SR1 has taught us more about the sorts of information ... monitoring is to provide feedback to the online operators, and to a monitoring shift crew about the ... or the last n events). ** PWP - during final operation, should this be tied to the luminosity block? ...
1K - last updated 2006-07-13 11:10 UTC by
SctRodDaq
SctRodDaq is the configuration, calibration, readout and analysis package for the ATLAS SCT. Please see ... Also, there is some information for the developers: * BuildingARelease * TestingARelease ...
1K - last updated 2006-02-12 13:47 UTC by
SctRodDaqRelease4
This release is the second major release for MacroAssembly and the [[SRBuilding]]. Lessons learned from ... by supporting a "recover from crash" operation, so that they can pick from where they left ...
4K - last updated 2005-02-14 12:09 UTC by
SctRodDaqRelease4.1.1
Bug fix release for [[SctRodDaqRelease4.1]]. [[SctRodDaqRelease4.1.1]] fixes a bug in [[SctRodDaqRelease4.1]] ... was caused by the newly added noise occupancy slopes, which were confusing sctGui's test-result summary ...
1K - last updated 2005-02-14 17:50 UTC by
SctRodDaqRelease4.3.RC1
See also [[SctRodDaqRelease4.3]]. == HOW CREATED == [[SctRodDaqRelease4.3.RC1]] was created on 15th Dec ... it seg faults, sometimes it gives an invalid operatation. gdb shows it dying when a dynamic_cast ...
6K - last updated 2005-12-19 11:21 UTC by
SctWeekTechnicalMeetingDec2003
I am proposing a technical meeting amongst the developers to discuss in detail what needs to be done ...
3K - last updated 2003-12-08 17:29 UTC by
ServiceStatusGUI
The ServiceStatusGUI keeps an eye on the performance of the service processes such as the ArchivingService, ... </pre> Note that the ServiceStatusGUI can cope even if the ServiceStatus IS server is absent when ...
1K - last updated 2007-12-14 15:01 UTC by
SettingUpDaqHardware
Instructions from JohnHill... There have been several occasions over the last couple of years where during ... I thought it was wise to put out this mail. I hope it is useful. I should point out that this mail ... being absolutely sure. Even if the SBC boots properly at power-up, this is no guarantee that it is ... in the ROD. 6) If the ROD is not behaving properly at this stage, please consult the experts - ...
1K - last updated 2005-03-24 01:22 UTC by
SlopesOnBarrelThree
The NPtGainTest produces noise, offset and gain channel by channel. Looking for systematic slopes across ... chips on run 2172 scan 3. ===Definition=== slope = average change per channel over chip. Distribution ... plots] ===Suggested Ranges for "normal"=== ... --> 0.07 * Gain -0.04 --> 0.04 ===Offset Slope=== *[http://www-pnp.physics.ox.ac.uk/~barra/WikiPlots/2172.3.20220170200008_Offset_1.eps ... ... abs (offset)>0.05 <pre> offset_slope sn row posn chip -0.0679006 20220040200067 12 6 ...
3K - last updated 2005-02-12 23:43 UTC by
SoftwareDevelopers
The people responsible for the SctRodDaq software are (in no particular order): * JanetCarter * PeterPhillips ...
1K - last updated 2006-02-11 21:11 UTC by
SoftwareTests
This is a list of the test systems and so on used to test the software. ===SystemTests=== SystemTests ... applications and critical functions. The developers are asked to code UnitTests whenever they come ...
1K - last updated 2004-07-02 16:11 UTC by
SortingOutDspCode
Mail from PeterPhillips 2005-10-07 <pre> Hi Trevor, Alan, Last time I looked at rod-sct-1-20, I ... what we have to do is drop, say the C code no ope histogram routine and put in full mode (still in ... C) instead. I don't think the speed is critical. OPE is there in both C and asm forms, however the asm ...
1K - last updated 2005-10-07 20:35 UTC by
SortingOutRodDaqRodCrate
All part of SortingOutRodDaq. Differences between the Oxford dev4/ version of RodCrate (also now used ... and the SctRodDaq_3_0_BRANCH, from which it developed. NOT YET IN CVS. <pre> [pcphsctr05] /home/sctroddq/sctsw/RodDaq ...
7K - last updated 2005-10-06 19:28 UTC by
Sr1Setup
==Overview== There are currently two main test systems in SR1: * H8 test box setup. Host machine srsctdaq1, ... sector is C3F8 chilled. Only trained cooling operators are permitted to operate the cooling. The ... SCT cooling operators are: * [[Dave]] * Jorgen * Ewa * Forest * ...
5K - last updated 2006-03-22 16:09 UTC by
SynchTriggerNoise
In the SynchTriggerNoise test, a trigger is sent at the same time to modules. An analysis for this data ... number of triggers sent and is set to 0. In the OPE for this test, the y-axis "Null Variable" represent, ... separate problems of varying seriousness and scope with synchTrigs, which was why the debugging has ... in the first bin! Affects: I'm not sure of the scope- certainly the November 2004 DSP code seems to ...
3K - last updated 2005-09-15 22:21 UTC by
SynchTriggerNoiseAnalysis
Analysis of the SynchTriggerNoise == Analysis of SynchTriggerNoise data from Alan Phillips: == The Following ... are more synchronous. 02/08/2005 15:58 The only OPE feature is on 20220170200257 from run 9482.0 at ... 0.95fC, there is one OPE blip. Nothing to worry about. But is there anything ... 1553.7 from CERN dataset. LMT 48 z-2 shows an OPE blip at threshold=1fC ...
1K - last updated 2005-10-11 15:16 UTC by
SystemTests
This is a list of comments/notes from my testing of SctRodDaq using the SystemTests stuff. * Using the ... are no address labels on the roller coaster envelopes. This is done by first pointing the archiving ...
3K - last updated 2007-12-14 15:52 UTC by
TIM
The TIM (TTC Interface Module) is the interface between the SCT off-detector electronics and the ATLAS ... The TIM is also capable of stand-alone operation, generating the signals as requested by the ...
1K - last updated 2004-07-16 12:10 UTC by
TestingSctRodDaq 4 1
I tested SctRodDaq_4_1 in pcei.hep.phy.cam.ac.uk:/usera/sctrod/testing_4_1 This <a href="http://www.hep.phy.cam.ac.uk/atlas/macro-assembly/DAQ/SctRodDaq_4_1/BinaryRelease.tar.gz">BinaryRelease</a> ... been reading these instrucations, and the developers. It was also necessary to do: cd /usera/sctrod/testing_4_1/SctRodDaq ... ERROR [IPCUtil::resolveInitialReference] cannot open reference file "/usera/sctrod/testing_4_1/SctRodDaq/ipc.ref.file": ...
3K - last updated 2005-02-21 16:38 UTC by
TestingSctRodDaq 4 2 RC1
I tested SctRodDaq_4_2_RC1 in pcei.hep.phy.cam.ac.uk:/usera/sctrod/testing_4_2_RC1 The binary release ... been reading these instrucations, and the developers. It was also necessary to do: cd /usera/sctrod/testing_4_2_RC1/SctRodDaq ... ERROR [IPCUtil::resolveInitialReference] cannot open reference file "/usera/sctrod/testing_4_2_RC1/SctRodDaq/ipc.ref.file": ...
3K - last updated 2007-04-23 09:22 UTC by
TestingSctRodDaq 4 3 RC1
See also [[SctRodDaqRelease4.3]] and [[TestingSctRodDaq_4_3_RC2]]. ----- I tested SctRodDaq_4_3_RC1 in ... been reading these instrucations, and the developers. It was also necessary to do: cd /usera/sctrod/testing_4_2_RC1/SctRodDaq ... and DDCHardware_template.data.xml. This is hopefully easy enough to do and only consisted of changing ... ERROR [IPCUtil::resolveInitialReference] cannot open reference file "/usera/sctrod/testing_4_3_RC1/SctRodDaq/ipc.ref.file" ...
3K - last updated 2007-04-23 09:22 UTC by
TestsForBarrelSix
==Barrel 6 Routine Assembly Tests== General - 16 bit histograms would speed up r/o time for most of these. ... ** unchanged * ThreePointGainTest ** including slope analysis, otherwise unchanged * NoiseOccupancyTest ... ** including [[OPE]] analysis, otherwise unchanged ** '''what about ... * need at least one threshold scan to look for slope variations ** [[Alan]] reminds himself that this ... is a slope across chips ** [[Alan]] asks himself if the NPtGain ...
3K - last updated 2005-02-23 14:26 UTC by
config server
From Bruce: <pre> At the moment config_server thinks it's a run controller. I presume running as ... part of SctRodDaq should start it properly. For running stand alone, something like: config_server ...
1K - last updated 2005-11-02 10:39 UTC by